Ignition transformers点火变压器,
TZI,不带安装盒
TGI 带安装盒 Ignition transformers TZI, TGI Ignition of gas burners Compact dimensions High operational reliability Ignition and burner monitoring possible with common electrode Cabinet or wall mounting Complying with VDE 0550 and IEC 989 T、ZI 7,5/33 is CSA-approved
相关的型号如下:
Type Input Output Constr. Protection Rating Weight
TZI 5/20T 230 50 (60) 0,5 (0,35) 5000 15 (11) A IP 20 20 % ED 4 0,9 TZI 5/100T 230 50 (60) 0,45 (0,35) 5000 15 (11) B IP 20 DB 5 1,5 TZI 7/20T 230 50 (60) 1,1 (0,8) 7000 25 (18) B IP 20 20 % ED 5 1,5 TZI 7,5/100T 230 50 (60) 0,6 (0,45) 7500 12 (9) B IP 20 DB 6 2 TZI 5/20N 115 50 (60) 1(0,7) 5000 15 (11) A IP 20 20 % ED 4 0,9 TZI 5/100N 115 50 (60) 0,9 (0,7) 5000 15 (11) B IP 20 DB 5 1,5 TZI 7/20N 115 50 (60) 2,2 (1,6) 7000 25 (18) B IP 20 20 % ED 5 1,5 TZI 7,5/100N 115 50 (60) 1,2 (0,9) 7500 12 (9) B IP 20 DB 6 2 TZI 7,5/33N 115 50 (60) 1,8 (1,35) 7500 20 (15) B IP 20 33 % ED 7 2 TGI 5/100T 230 50 (60) 0,45 (0,35) 5000 15 (11) C IP 65 DB 8 3 TGI 7/20T 230 50 (60) 1,1 (0,8) 7000 25 (18) C IP 65 20 % ED 8 3 TGI 7,5/100T 230 50 (60) 0,6 (0,45) 7500 12 (9) C IP 65 DB 8 3,5 TGI 5/100N 115 50 (60) 0,9 (0,7) 5000 15 (11) C IP 65 DB 8 3 TGI 7/20N 115 50 (60) 2,2 (1,6) 7000 25 (18) C IP 65 20 % ED 8 3 TGI 7,5/100N 115 50 (60) 1,2 (0,9) 7500 12 (9) C IP 65 DB 8 3,5 Application Ignition transformers for high-voltage ignition of gas burners and gas-ignited or directly ignited oil burners. Can also be used on burners on which only one electrode is available for ignition and monitoring. Installation TZI, open, for cabinet mounting, TGI, enclosed, for wall mounting Recommended fitting position: connections pointing downwards. |